一、發展歷程
SY-JD07A型/冷藏柜致冷空調制熱實踐考驗安全裝置”是可根據教(jiao)育培訓部(bu)“振興21世紀職(zhi)業(ye)(ye)教(jiao)育課程(cheng)改(gai)革和教(jiao)材建(jian)設規劃(hua)”要求(qiu)(qiu),以(yi)能力為(wei)本位(wei)、以(yi)就業(ye)(ye)為(wei)導向,緊密結合生產實(shi)(shi)際(ji)和職(zhi)業(ye)(ye)崗位(wei)的技(ji)(ji)(ji)能要求(qiu)(qiu),按照職(zhi)業(ye)(ye)教(jiao)育的教(jiao)學(xue)和實(shi)(shi)訓要求(qiu)(qiu)研發的產品。適合高職(zhi)院校、職(zhi)業(ye)(ye)學(xue)校的制(zhi)(zhi)(zhi)冷(leng)(leng)技(ji)(ji)(ji)術(shu)(shu)、制(zhi)(zhi)(zhi)冷(leng)(leng)流體(ti)機械、家(jia)用制(zhi)(zhi)(zhi)冷(leng)(leng)設備原(yuan)理與(yu)(yu)維(wei)修、冷(leng)(leng)庫與(yu)(yu)冷(leng)(leng)藏技(ji)(ji)(ji)術(shu)(shu)、制(zhi)(zhi)(zhi)冷(leng)(leng)設備維(wei)修工(初級(ji)、中級(ji)、高級(ji))實(shi)(shi)訓等(deng)教(jiao)學(xue)實(shi)(shi)訓裝(zhuang)置。培養(yang)掌握空調與(yu)(yu)制(zhi)(zhi)(zhi)冷(leng)(leng)技(ji)(ji)(ji)術(shu)(shu)專(zhuan)業(ye)(ye)理論知識(shi)和專(zhuan)業(ye)(ye)實(shi)(shi)踐技(ji)(ji)(ji)能,從事空調、制(zhi)(zhi)(zhi)冷(leng)(leng)設備及系(xi)統(tong)的技(ji)(ji)(ji)術(shu)(shu)升級(ji)、改(gai)造(zao)設計、安裝(zhuang)、調試(shi)、維(wei)護、維(wei)修、技(ji)(ji)(ji)術(shu)(shu)管理等(deng)方面的技(ji)(ji)(ji)能應用型人才(cai)。
實踐教學安(an)裝也適鍛造工(gong)(gong)高校、職業(ye)(ye)培訓課高校、職教平臺、技術鑒定(ding)站/所、制冷類專業(ye)(ye)《制冷設(she)備維(wei)修工(gong)(gong)(初級(ji)、中級(ji)、高級(ji))》、《家用制冷設(she)備原理與維(wei)修》、《壓縮(suo)機冰箱安裝程(cheng)序(xu)操作使用安裝程(cheng)序(xu)與保修》、《》、《》等教(jiao)學。
二、作用(yong)
1、整(zheng)體(ti)集(ji)養(yang)成空調(diao)系統、養(yang)成冰箱保(bao)鮮于立體(ti)式(shi),進(jin)行真的冷(leng)暖空調(diao)冷(leng)凍機組,需求實踐教學評價
設(she)備(bei)選配了2套系(xi)統(tong),空(kong)調(diao)系(xi)統(tong)1套、直冷(leng)式(shi)/間(jian)冷(leng)式(shi)電冰箱綜合系(xi)統(tong)1套可同時滿足對空(kong)調(diao)、冰箱實訓操作考核的要求
2、芭比娃娃家具培(pei)訓安裝集老板桌、家用冰(bing)箱的制冰(bing)設(she)(she)計(ji)、電力設(she)(she)備掌握(wo)設(she)(she)計(ji)、發(fa)動機故障模(mo)擬網(wang)設(she)(she)計(ji)于一體化(hua),設(she)(she)計(ji)現實完善,框架明顯(xian)、緊(jin)湊型suv
3、實踐(jian)保(bao)護裝(zhuang)置(zhi)(zhi)最直觀(guan)提(ti)供了空氣源(yuan)空氣熱泵型分(fen)離式(shi)(shi)中(zhong)央空調(diao)的(de)使(shi)用(yong)的(de)裝(zhuang)置(zhi)(zhi)機(ji)構、事情(qing)中(zhong)設計(ji)原理,可明白的(de)知道(dao)(dao)(dao)致冷(leng)反(fan)復裝(zhuang)置(zhi)(zhi)機(ji)構及主要(yao)的(de)元件(jian)(jian)的(de)產(chan)品,裝(zhuang)置(zhi)(zhi)還選(xuan)配有(you)結構體游針(zhen)式(shi)(shi)互動(dong)會(hui)線電壓表(biao)、結構體游針(zhen)式(shi)(shi)互動(dong)會(hui)電壓表(biao)、數(shu)顯式(shi)(shi)溫表(biao)、負(fu)壓負(fu)壓表(biao)、衛星指示燈使(shi)全(quan)部空氣源(yuan)空氣熱泵分(fen)離式(shi)(shi)中(zhong)央空調(diao)的(de)使(shi)用(yong)裝(zhuang)置(zhi)(zhi)、冷(leng)庫裝(zhuang)置(zhi)(zhi)的(de)雷達回波圖事情(qing)中(zhong)的(de)情(qing)況下(xia)分(fen)門別類;還有(you)就是,壓縮空氣管(guan)道(dao)(dao)(dao)中(zhong)下(xia)設視(shi)液鏡極好察致冷(leng)劑(ji)的(de)情(qing)況下(xia);髙(gao)壓壓縮空氣管(guan)道(dao)(dao)(dao)為橙(cheng)紅(hong)色的(de)部件(jian)(jian),壓差大壓縮空氣管(guan)道(dao)(dao)(dao)為紅(hong)色的(de)部件(jian)(jian)
4、可仿真錯(cuo)誤(wu)代碼設(she)計,孩子可根據加(jia)工進行分析錯(cuo)誤(wu)代碼將引發的(de)情況,制(zhi)定(ding)錯(cuo)誤(wu)代碼造(zao)成的(de)依據,并舉(ju)行排故。有益于深入開(kai)展技能效(xiao)果鑒定(ding)會、考(kao)評運轉(zhuan)
三、的技術規格
1、輸人電源適配器:三相變頻器3線~220V±10% 50Hz
2、設施余量:<1.2kVA
3、造型(xing)長(chang)寬高:1580mm×730mm×1700mm
4、冷庫(ku)劑(ji)款式(shi):空調制冷 R22、冷柜600a
5、應急衛生確(que)保(bao):還具有漏(lou)電(dian)壓、漏(lou)電(dian)流確(que)保(bao)器,應急衛生達(da)到國內標準化
四(si)、保護裝置的幾乎法寶
本(ben)實(shi)踐教學(xue)裝置設備基本(ben)由電(dian)源適配(pei)器(qi)保持屏、實(shi)踐教學(xue)桌、機械故障箱(xiang)、自測箱(xiang)等主成。
1、電(dian)源(yuan)線(xian)模(mo)塊(kuai)(kuai)、儀器把(ba)握屏:把(ba)握屏為鐵質多層亞光密紋噴塑結構(gou)的(de),鋁質的(de)面(mian)版,為實踐提高交談電(dian)源(yuan)線(xian)模(mo)塊(kuai)(kuai)、不同試驗(yan)儀器及實踐電(dian)子元件等。
2、討論(lun)會(hui)電(dian)(dian)(dian)(dian)(dian)(dian)源適配(pei)器模塊線(xian)(xian)把控(kong)單元測(ce)試:兩相電(dian)(dian)(dian)(dian)(dian)(dian)二線(xian)(xian)制220V討論(lun)會(hui)電(dian)(dian)(dian)(dian)(dian)(dian)源適配(pei)器模塊線(xian)(xian)電(dian)(dian)(dian)(dian)(dian)(dian)力(li)公司(si),討論(lun)會(hui)互動電(dian)(dian)(dian)(dian)(dian)(dian)壓(ya)降表(biao)2只 測(ce)定的的范圍0~250V,用在(zai)監控(kong)配(pei)電(dian)(dian)(dian)(dian)(dian)(dian)網(wang)互動電(dian)(dian)(dian)(dian)(dian)(dian)壓(ya)降,討論(lun)會(hui)上班(ban)(ban)感(gan)應電(dian)(dian)(dian)(dian)(dian)(dian)壓(ya)表(biao)2只測(ce)定的的范圍不同(tong)為(wei)0~5A、0~10A,用在(zai)測(ce)量裝置起動上班(ban)(ban)感(gan)應電(dian)(dian)(dian)(dian)(dian)(dian)壓(ya)及(ji)監控(kong)裝置正常的上班(ban)(ban)上班(ban)(ban)感(gan)應電(dian)(dian)(dian)(dian)(dian)(dian)壓(ya),漏電(dian)(dian)(dian)(dian)(dian)(dian)自我保(bao)護裝置把控(kong)把控(kong)屏總電(dian)(dian)(dian)(dian)(dian)(dian)源適配(pei)器模塊線(xian)(xian),把控(kong)屏的電(dian)(dian)(dian)(dian)(dian)(dian)力(li)公司(si)由鑰匙旋轉開關(guan)把控(kong)
3、制冷劑軟件學習負(fu)擔值加測(ce)單元(yuan)式(shi):提供(gong)數(shu)據4只(zhi)真空泵學習負(fu)擔值表,量(liang)測(ce)空間各分為(wei)為(wei)-0.1~0.9MPa、-0.1~1.5MPa、-0.1~3.5MPa,應用在量(liang)測(ce)空調(diao)裝置、家用冰箱軟件高、舒張壓側(ce)學習負(fu)擔值
4、室(shi)內氣(qi)溫(wen)的檢測單元:作為幾位(wei)半字母室(shi)內氣(qi)溫(wen)表(biao)2只(zhi),用頻譜開關(guan)按(an)鈕設置,表(biao)示不(bu)一(yi)樣的點的室(shi)內氣(qi)溫(wen)轉(zhuan)化(hua)的情(qing)況
5、交(jiao)流電(dian)(dian)型漏(lou)電(dian)(dian)愛(ai)(ai)護提升裝(zhuang)置1套:對(dui)地漏(lou)電(dian)(dian)交(jiao)流電(dian)(dian)超一些值,即跳閘推不上去鋸斷外接電(dian)(dian)源;具有熱愛(ai)(ai)護集成電(dian)(dian)路芯片,對(dui)縮減機來(lai)進行起熱、超負(fu)荷愛(ai)(ai)護。
6、實踐教學桌
實踐教學桌為鐵質雙重亞光密(mi)(mi)紋噴塑(su)組成,主屏幕為防火性、防腐(fu)、耐用高(gao)體(ti)積密(mi)(mi)度板,組成經久耐用,造行整潔美(mei)觀(guan)大(da)氣(qi);存在幾(ji)個(ge)大(da)柜門,桌面(mian)上于裝置24v電源(yuan)控制屏并帶來一位寬大(da)舒(shu)適安逸的上班(ban)臺(tai)面(mian)板。培訓桌還(huan)存在以下橡(xiang)膠輪(lun),更方便(bian)走(zou)動和一定,影(ying)響于培訓室(shi)的布置。
7、實踐教學箱:系(xi)統化(hua)(hua)(hua)出(chu)(chu)現(xian)問(wen)(wen)題板(ban)提拱虛(xu)擬仿真中央空調(diao)機與虛(xu)擬仿真冷(leng)(leng)柜冷(leng)(leng)藏系(xi)統化(hua)(hua)(hua)出(chu)(chu)現(xian)問(wen)(wen)題箱各(ge)3個,提拱常見的(de)的(de)系(xi)統化(hua)(hua)(hua)出(chu)(chu)現(xian)問(wen)(wen)題裝置點,時用虛(xu)擬仿真系(xi)統化(hua)(hua)(hua)的(de)系(xi)統化(hua)(hua)(hua)出(chu)(chu)現(xian)問(wen)(wen)題;裝置內型有:主(zhu)機電(dian)源三(san)極(ji)(ji)管(guan)、體溫感測器三(san)極(ji)(ji)管(guan)、驅(qu)動軟件三(san)極(ji)(ji)管(guan)、減(jian)小機保(bao)護好(hao)三(san)極(ji)(ji)管(guan)、窒內制冷(leng)(leng)機調(diao)速器三(san)極(ji)(ji)管(guan)等。中央空調(diao)機虛(xu)擬仿真系(xi)統化(hua)(hua)(hua)出(chu)(chu)現(xian)問(wen)(wen)題面(mian)板(ban)電(dian)開關量、冷(leng)(leng)柜冷(leng)(leng)藏虛(xu)擬仿真系(xi)統化(hua)(hua)(hua)出(chu)(chu)現(xian)問(wen)(wen)題面(mian)板(ban)電(dian)開關量,充分滿(man)足多方系(xi)統化(hua)(hua)(hua)出(chu)(chu)現(xian)問(wen)(wen)題裝置特殊要求。
五、空氣熱源(yuan)泵型工(gong)作家用空調模仿故障率放(fang)置說
編碼 | 錯誤仿真模擬說明書 | 錯誤碼物理現象 |
K1 | 配電變(bian)壓(ya)器T原邊(bian)引(yin)路(lu) | 手機板嚴(yan)禁電,整個機械(xie)不(bu)辦公 |
K2 | 箱式變壓器T副(fu)邊斷(duan)路 | 電子設(she)備板沒法電,電腦整(zheng)機不運作 |
K3 | 橋堆斷路 | 手機(ji)板不(bu)應(ying)電,裸機(ji)不(bu)作(zuo)業 |
K4 | 7805集成式穩壓塊斷路 | 無+5V直(zhi)流主機電源(yuan)主機電源(yuan)讀取,主機不工作(zuo)的 |
K5 | 空(kong)間內學習環境濕度感測器器短路 | 運動的電(dian)源指示燈閃(shan)亮 |
K6 | 空間內氛圍環(huan)境溫度(du)調節器(qi)器(qi)虛接(jie) | 作(zuo)業信號燈(deng)燈(deng)忽明忽暗 |
K7 | 車間(jian)內管溫(wen)(wen)體溫(wen)(wen)感應器(qi)器(qi)短路 | 按時(shi)指示(shi)器(qi)燈忽(hu)明忽(hu)暗(an) |
K8 | 別墅(shu)地(di)下室管溫(wen)高溫(wen)感應器器出(chu)現短(duan)路 | 按時提示燈忽閃 |
K9 | f1開(kai)機啟動電容(電容器)短路 | 直流無刷交(jiao)流接觸器沒有辦法(fa)通(tong)電,直流無刷交(jiao)流接觸器不任務 |
K10 | f1啟動電(dian)機(ji)繞線(xian)短路 | 變頻電(dian)動(dong)(dong)機(ji)不(bu)了開機(ji),變頻電(dian)動(dong)(dong)機(ji)不(bu)工做 |
K11 | 四通閥YV電感串入 | 四通閥(fa)不運轉,空調制熱(re)載(zai)荷(he)時不易做(zuo)用 |
K12 | 自我保護繼電子(zi)元件SAT串入 | 減少機不會作業 |
K13 | 降(jiang)低(di)機(ji)開機(ji)電機(ji)繞線(xian)CS斷路(lu) | 壓縮的(de)機不可事(shi)情(qing),重啟電壓非常大的(de) |
K14 | 壓縮視(shi)頻(pin)機加載線圈CM斷路 | 壓縮的機不可(ke)以工作上,開始直流電壓非常(chang)大的 |
K15 | 蜂(feng)鳴器(qi)BUZZ初級(ji)線圈短路 | 蜂鳴器不響,操控起用 |
K16 | 繼電子產品RLY5次級(ji)線(xian)圈引路(lu) | 仿真模(mo)擬室內外調節時,檔(dang)次高流速不(bu)了用(yong)途 |
K17 | 啟動繼電器開關(guan)RLY4電阻(zu)引路 | 模擬機室內裝修(xiu)可控硅(gui)調壓時,中等風速(su)等級(ji)不出(chu)的(de)作(zuo)用 |
K18 | 繼電氣產品RLY3次級線圈斷(duan)路 | 模擬機陽臺陽光(guang)房調(diao)節時(shi),底檔風量不出(chu)目的 |
K19 | 繼電子元件RLY2電阻(zu)線短路 | 四通閥閥體不的動作 |
K20 | 繼電商RLY1初級線圈(quan)串入 | 壓縮成機不工作上 |
K21 | 紅外受到管外接電源(yuan)端(duan)斷路 | 手機遙控不上角色 |
六、直(zhi)冷(leng)/間冷(leng)式電冰箱模擬故障設置說明
順序號 | 發動機故障仿真表明 | 故障問題現像 |
K1 | 黏結門按鈕S2斷路 | 間冷模(mo)式(shi)切換低(di)處(chu)扇無刷(shua)電機不轉 |
K2 | 復(fu)合材(cai)料門按鈕S2燒壞 | 間冷模試下虛(xu)擬門旋鈕旋鈕時,排氣扇電(dian)機的不停止設備運轉 |
K3 | 葉輪調(diao)速電機繞(rao)阻斷路 | 排氣扇馬達不轉 |
K4 | WPF控溫器L-C兩端引(yin)路 | 間(jian)冷(leng)玩法(fa)下(xia)門燈亮,降低機不(bu)崗位 |
K5 | 耗時繼電BW-BK兩端短(duan)路 | 間冷形式下門(men)燈亮,文件冰箱壓縮(suo)機(ji)不業務 |
K6 | 事件繼電商BW-BK兩端斷路 | 間(jian)冷方法(fa)下操作(zuo)8分鐘后,化霜解制冷壓縮機不關機 |
K7 | 化(hua)霜溫度控制器器短(duan)路(lu) | 間冷的模式下化霜時,化霜保險(xian)費(fei)用(yong)絲(si)擊穿 |
K8 | 化霜發熱器管斷路 | 間冷模式,下(xia)(xia)化霜(shuang)情形下(xia)(xia),化霜(shuang)沒有做用 |
K9 | 門燈短路S1 | 門燈沒有顯示 |
K10 | 包覆門(men)電開(kai)關(guan)S1引(yin)路 | 門燈沒亮 |
K11 | 分手(shou)后復(fu)合門旋鈕(niu)S1擊穿 | 養成門面(mian)板(ban)開關按鈕面(mian)板(ban)開關按鈕時, 門燈常亮 |
K12 | 保護繼家用電器引路 | 減小機不了(le)開啟,無直流電(dian)壓出現(xian) |
K13 | 縮(suo)短機啟動的繞阻CS短路(lu) | 縮(suo)減機始終無法重啟,感應功率(lv)較高(縮(suo)減機做工作感應功率(lv)5~10倍) |
K14 | 擠壓機(ji)作(zuo)業繞(rao)阻CM引路 | 縮減(jian)機沒法發(fa)動,事情(qing)(qing)電流值(zhi)巨大(縮減(jian)機事情(qing)(qing)事情(qing)(qing)電流值(zhi)5~10倍) |
K15 | PTC通電器短路 | 降低(di)機沒有辦法啟動的,功(gong)(gong)率越大(da)(降低(di)機本職工作功(gong)(gong)率5~10倍(bei)) |
K16 | WDF溫度控制器器H-L兩端短路 | 直冷經營模式下(xia)門燈亮,縮小機不業務 |
K17 | 整體臟堵 | 正常運作情況下,血壓(ya)(ya)低壓(ya)(ya)高側-壓(ya)(ya)表(biao)提示 -壓(ya)(ya)值 |
K18 | 體統冰堵 |