“SYJYD-01F冷(leng)(leng)(leng)庫(ku)安(an)(an)裝(zhuang)小(xiao)(xiao)編(bian)降(jiang)低的(de)機(ji)耐(nai)磨性測(ce)試(shi)英文實踐培訓 設(she)施”主要包(bao)括過熱蒸(zheng)汽(qi)降(jiang)低的(de)式冷(leng)(leng)(leng)庫(ku)安(an)(an)裝(zhuang)小(xiao)(xiao)編(bian)循壞控制機(ji)系統(tong),設(she)備(bei)全密封式性式冷(leng)(leng)(leng)庫(ku)安(an)(an)裝(zhuang)小(xiao)(xiao)編(bian)降(jiang)低的(de)機(ji)、冷(leng)(leng)(leng)凝劑器(qi)、空調蒸(zheng)發器(qi)器(qi)等冷(leng)(leng)(leng)庫(ku)安(an)(an)裝(zhuang)小(xiao)(xiao)編(bian)控制機(ji)系統(tong)實際(ji)配件(jian),并包(bao)括智慧溫度因素調控儀、流量(liang)的(de)計(ji)、負壓表、工作(zuo)電(dian)壓表、交流電(dian)表等預(yu)估儀器(qi)儀表。雖然能(neng)創辦冷(leng)(leng)(leng)庫(ku)安(an)(an)裝(zhuang)小(xiao)(xiao)編(bian)降(jiang)低的(de)機(ji)耐(nai)磨性大(da)多參數的(de)測(ce)量(liang)實踐培訓 ,還能(neng)來進行(xing)冷(leng)(leng)(leng)庫(ku)安(an)(an)裝(zhuang)小(xiao)(xiao)編(bian)循壞大(da)多關鍵(jian)技術(shu)的(de)演(yan)繹實踐培訓 。實用以職業類型(xing)本(ben)科院校冷(leng)(leng)(leng)庫(ku)安(an)(an)裝(zhuang)小(xiao)(xiao)編(bian)正規(gui)有關系課程(cheng)培訓的(de)培訓 實踐培訓 。
一(yi)、 傳動(dong)裝置優勢
1.本實踐教學安裝(zhuang)安裝(zhuang)展覽細則GB/T 5773-2004溶量式(shi)安真小編壓縮的(de)機耐熱(re)性實踐教學的(de)方式(shi)建造(zao),以“化掉器溶劑載冷劑不斷循環法(fa)”居(ju)多要(yao)估(gu)測,以“油冷空氣冷卻(que)器量熱(re)器法(fa)”是協助估(gu)測
2.采(cai)用了(le)1匹(pi)空(kong)調制熱設備,蒸汽加熱器(qi)(qi)和(he)蒸發(fa)掉器(qi)(qi)均(jun)為殼管(guan)式水(shui)熱交換器(qi)(qi)器(qi)(qi),裝置結構類型密集、布置圖合理安排,設計顏值大度
3.具有(you)的電壓型漏電護(hu)理(li)(li)(li)、電流(liu)大小(xiao)型漏電護(hu)理(li)(li)(li)、過流(liu)護(hu)理(li)(li)(li)、超負(fu)荷護(hu)理(li)(li)(li)、接(jie)地線護(hu)理(li)(li)(li),可對人身事故及機(ji)器完成有(you)用護(hu)理(li)(li)(li)
二、 技(ji)木(mu)使用(yong)性(xing)能(neng)
1.進入主機電源:三相(xiang)變(bian)頻器四(si)線~220V±10% 50Hz
2.任務場景:水溫-10℃~+40℃ 相(xiang)比空氣(qi)濕度<85%(25℃) 海拔高度<4000m
3.傳(chuan)動(dong)裝置存儲空(kong)間:<2.5kVA
4.制熱劑:R22
5.空調制(zhi)冷量:1.3kW
6.重 量:100kg
7.外觀的尺(chi)寸:120cm×60cm×142cm
三、 大多配值及職能
1.操縱屏
采取單層亞光密紋噴塑節構,造形新(xin)意。最頂部設計(ji)空(kong)調制(zhi)熱(re)機軟(ruan)(ruan)件,可直觀性 動態展(zhan)示空(kong)調制(zhi)熱(re)機軟(ruan)(ruan)件節構;背面配有電源(yuan)適配器把控(kong)及測量方(fang)法設備能力(li)板。下方(fang)都有4個帶剎車踏板的(de)萬向腳輪,更(geng)好地手機移(yi)動和進(jin)行(xing)固定。
2.聊天操作單元測試
兩相電(dian)(dian)(dian)3線220V交換開關(guan)電(dian)(dian)(dian)源模塊共(gong)電(dian)(dian)(dian),經漏(lou)電(dian)(dian)(dian)流值維(wei)護器操縱總(zong)開關(guan)電(dian)(dian)(dian)源模塊,過程電(dian)(dian)(dian)流值30mA
3.空調制熱體統
1匹全封閉(bi)室式縮(suo)減機、臥(wo)式殼(ke)管(guan)式冷凝劑器(qi)(qi)(qi)、視液(ye)(ye)鏡(jing)、烘干(gan)過濾裝置(zhi)器(qi)(qi)(qi)、手動操(cao)作時節流(liu)閥、儲液(ye)(ye)器(qi)(qi)(qi)和(he)自吸式揮發(fa)器(qi)(qi)(qi)
4.無(wu)限循環(huan)人工濕地(di)統
(1) 自(zi)吸泵2只(zhi)
主要(yao)的方(fang)法性(xing)能參數為(wei):
額定(ding)負(fu)載工(gong)作(zuo)效率:95W
固定揚程:6m
電機額定(ding)功率水流量(liang):1.08每立方米/小時
(2) 中冷器2只
所采用(yong)不銹(xiu)不銹(xiu)鋼(gang)材質鋼(gang)素材制作成,各是為冷(leng)凝劑(ji)器循壞系(xi)統(tong)水廂和化掉器循壞系(xi)統(tong)水廂
(3) 熱處(chu)理加熱板(ban)1只(zhi)(輸(shu)出1000W)
傷害效率可經(jing)過(guo)電位差器來進行調控(kong),廣(guang)泛用于燒水減壓蒸餾器循壞水
5.量測義表
(1) 工率表(biao)2只(zhi)(要求(qiu)0.5級)
差(cha)別測(ce)定燒水熱(re)效(xiao)率(lv)(lv)和減少機熱(re)效(xiao)率(lv)(lv)。需要通(tong)過鍵控、數(shu)顯儀表窗口最(zui)大化(hua)達成組(zu)隊情景(jing)對話的(de)智能(neng)化(hua)操縱模(mo)試,可(ke)測(ce)定電機電流的(de)有功熱(re)效(xiao)率(lv)(lv)、無功熱(re)效(xiao)率(lv)(lv)、熱(re)效(xiao)率(lv)(lv)質條(tiao)件、直流電壓、電壓、速(su)率(lv)(lv)及電機電流的(de)成分;并(bing)需要放置、了(le)解(jie)15組(zu)熱(re)效(xiao)率(lv)(lv)和熱(re)效(xiao)率(lv)(lv)質條(tiao)件的(de)各(ge)種測(ce)試報(bao)告文件
(2) 數顯儀(yi)表熱度(du)表1只(導致精度(du)0.5級(ji))
選擇PT100鉑熱敏電阻作(zuo)感應器(qi)(qi)(qi)(qi)器(qi)(qi)(qi)(qi),在測(ce)量(liang)空(kong)(kong)間-50~150℃。憑借琴鍵展開切回,共測(ce)8組工(gong)(gong)作(zuo)溫(wen)(wen)(wen)差(cha)基本參數,各自為壓(ya)解機吸(xi)氣口(kou)工(gong)(gong)作(zuo)溫(wen)(wen)(wen)差(cha)、壓(ya)解機res排氣口(kou)工(gong)(gong)作(zuo)溫(wen)(wen)(wen)差(cha)、空(kong)(kong)調汽(qi)(qi)(qi)化(hua)(hua)器(qi)(qi)(qi)(qi)器(qi)(qi)(qi)(qi)進口(kou)量(liang)工(gong)(gong)作(zuo)溫(wen)(wen)(wen)差(cha)、汽(qi)(qi)(qi)化(hua)(hua)器(qi)(qi)(qi)(qi)進口(kou)量(liang)工(gong)(gong)作(zuo)溫(wen)(wen)(wen)差(cha)、空(kong)(kong)調汽(qi)(qi)(qi)化(hua)(hua)器(qi)(qi)(qi)(qi)器(qi)(qi)(qi)(qi)水(shui)進口(kou)工(gong)(gong)作(zuo)溫(wen)(wen)(wen)差(cha)、空(kong)(kong)調汽(qi)(qi)(qi)化(hua)(hua)器(qi)(qi)(qi)(qi)器(qi)(qi)(qi)(qi)出(chu)液出(chu)液部(bu)位工(gong)(gong)作(zuo)溫(wen)(wen)(wen)差(cha)、汽(qi)(qi)(qi)化(hua)(hua)器(qi)(qi)(qi)(qi)水(shui)進口(kou)工(gong)(gong)作(zuo)溫(wen)(wen)(wen)差(cha)和汽(qi)(qi)(qi)化(hua)(hua)器(qi)(qi)(qi)(qi)出(chu)液出(chu)液部(bu)位工(gong)(gong)作(zuo)溫(wen)(wen)(wen)差(cha)
(3) 重力作用心理壓(ya)差表(biao)2只(計算精度2.5級)
測(ce)定范圍為-0.1~1.5MPa和(he)-0.1~3.5MPa,依(yi)次實(shi)時的測(ce)定冷庫安裝小編系統非(fei)進行高壓側負擔值和(he)進行高壓側負擔值
(4) 的水流量計2只(導致(zhi)精度0.5級(ji))
選擇(ze)窗玻璃定子精準流量(liang)的計,滿(man)量(liang)程為16~160ml/min,各是衡量(liang)冷疑器和(he)揮發(fa)器放涼河水量(liang)的
6.把控儀器
水準壓(ya)(ya)(ya)(ya)(ya)壓(ya)(ya)(ya)(ya)(ya)為(wei)管(guan)(guan)理器(qi)1只(zhi):進行檢測空調制熱模式壓(ya)(ya)(ya)(ya)(ya)差大(da)側壓(ya)(ya)(ya)(ya)(ya)為(wei)和高(gao)有(you)壓(ya)(ya)(ya)(ya)(ya)力(li)側壓(ya)(ya)(ya)(ya)(ya)為(wei),當高(gao)有(you)壓(ya)(ya)(ya)(ya)(ya)力(li)超(chao)過調節(jie)值或(huo)壓(ya)(ya)(ya)(ya)(ya)差大(da)壓(ya)(ya)(ya)(ya)(ya)低調節(jie)值時,管(guan)(guan)理器(qi)提出管(guan)(guan)理訊號剪斷(duan)收(shou)縮機電(dian)原
四、 培訓投資項目
1.認識液體減少式壓縮機循環設備設備的基(ji)本性節構(gou)和運行遠離
2.清楚知(zhi)名準則GB/T5773—2004容(rong)積怎么算(suan)式空調制熱擠壓機的性能便用辦(ban)法(fa)
3.運用冷(leng)(leng)疑器器液(ye)狀體載(zai)冷(leng)(leng)劑巡(xun)環法(fa)(主測(ce)法(fa))求解(jie)(jie)壓(ya)宿(su)機解(jie)(jie)壓(ya)宿(su)機解(jie)(jie)壓(ya)宿(su)機量
4.應用水冷散熱(re)(re)蒸汽加熱(re)(re)器(qi)熱(re)(re)穩(wen)定法(輔(fu)測法)求空(kong)調制泠壓縮成機空(kong)調制泠量
5.主(zhu)、輔測空調制制熱量對于差值的確定與分析一下
6.制冰汽輪發電機(ji)一級能耗(hao)的計算(suan)公式與分(fen)折